Review




Structured Review

Tecniplast inc digital ventilated cages dvc
Digital Ventilated Cages Dvc, supplied by Tecniplast inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/digital+ventilated+cage+(dvc)+system/digital+ventilated+cages/pmc12266724-463-7-11
Average 90 stars, based on 1 article reviews
digital ventilated cages dvc - by Bioz Stars, 2026-10
90/100 stars

Images

Related Articles

Activity Assay:

Article Title: Accurate locomotor activity profiles of group-housed mice derived from home cage monitoring data
Article Snippet: .. Many different types of devices exist to measure activity of laboratory mice, including Sable Systems Promethion , Columbus Instruments CLAMS/OxyMax , Tecniplast DVC (Digital Ventilated Cage system) , TSE systems LabMaster/PhenoMaster , and open field activity monitoring system ( ) or video-based home cage recording systems ( ) often combined with artificial intelligence for evaluation ( ). ..

Article Title: Sex-specific changes in energy demand during the preplaque stage in a transgenic Alzheimer’s mouse model
Article Snippet: .. Mice were predominantly pair-housed with a 12-hour light/dark cycle in individually ventilated cages or in the Digital Ventilated Cage system (DVC, Tecniplast), which continuously monitors intracage activity. ..

Article Title: Computational and digital analyses in the INSPIRE mouse cohort to define sex-specific functional determinants of biological aging.
Article Snippet: .. 10, eadt1670 (2024) 13 December 2024 13 of 16 Spontaneous mobility and voluntary activity Activity metrics were assessed through home- cage monitoring system Digital Ventilated Cage (DVC) manufactured by Tecniplast SpA (Buguggiate, Italy). ..

other:

Article Title: Computational and digital analyses in the INSPIRE mouse cohort to define sex-specific functional determinants of biological aging
Article Snippet: Activity metrics were assessed through home-cage monitoring system Digital Ventilated Cage (DVC) manufactured by Tecniplast SpA (Buguggiate, Italy).

Article Title: Abstracts to the 16th FELASA Congress 2025.
Article Snippet: s to the 16th FELASA Congress 2025

Article Title: Accurate locomotor activity profiles of group-housed mice derived from home cage monitoring data.
Article Snippet: Many different types of devices exist to measure activity of laboratory mice, including Sable Systems Promethion (Soto et al., 2019), Columbus Instruments CLAMS/OxyMax (Soto et al., 2019), Tecniplast DVC (Digital Ventilated Cage system) (Iannello, 2019), TSE systems LabMaster/PhenoMaster (Frenz et al., 1995), and open field activity monitoring system (Tatem et al., 2014) or video-based home cage recording systems (Salem et al., 2024) often combined with artificial intelligence for evaluation (Kopaczka et al., 2019).

Article Title: Evaluation of the Digital Ventilated Cage® system for circadian phenotyping.
Article Snippet: By leveraging capacitive sensor technology and real-time data analytics, the Digital Ventilated Cage (DVC) system (Tecniplast SpA, Italy), presents a novel solution to these challenges.

Mouse Assay:

Article Title: Sex-specific changes in energy demand during the preplaque stage in a transgenic Alzheimer’s mouse model
Article Snippet: .. Mice were predominantly pair-housed with a 12-hour light/dark cycle in individually ventilated cages or in the Digital Ventilated Cage system (DVC, Tecniplast), which continuously monitors intracage activity. ..



Similar Products

90
Tecniplast inc digital ventilated cages dvc
Digital Ventilated Cages Dvc, supplied by Tecniplast inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/digital+ventilated+cage+(dvc)+system/digital+ventilated+cages/pmc12266724-463-7-11
Average 90 stars, based on 1 article reviews
digital ventilated cages dvc - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Tecniplast inc digital ventilated cages (dvcs)
Digital Ventilated Cages (Dvcs), supplied by Tecniplast inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/digital+ventilated+cage+(dvc)+system/digital+ventilated+cages/pmc12188752-99-4-9
Average 90 stars, based on 1 article reviews
digital ventilated cages (dvcs) - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Tecniplast inc digital ventilated cage (dvc) system
Digital Ventilated Cage (Dvc) System, supplied by Tecniplast inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/digital+ventilated+cage+(dvc)+system/digital+ventilated+cages/pm40452454-5360-1-8
Average 90 stars, based on 1 article reviews
digital ventilated cage (dvc) system - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Tecniplast inc digitally ventilated cages dvc
Digitally Ventilated Cages Dvc, supplied by Tecniplast inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/digital+ventilated+cage+(dvc)+system/digital+ventilated+cages/pm40452454-7233-7-9
Average 90 stars, based on 1 article reviews
digitally ventilated cages dvc - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Tecniplast inc digitally ventilated cage dvc
Digitally Ventilated Cage Dvc, supplied by Tecniplast inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/digital+ventilated+cage+(dvc)+system/digital+ventilated+cages/pm40452454-5195-4-7
Average 90 stars, based on 1 article reviews
digitally ventilated cage dvc - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Tecniplast inc digitally ventilated cages (dvc) platform
Digitally Ventilated Cages (Dvc) Platform, supplied by Tecniplast inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/digital+ventilated+cage+(dvc)+system/digital+ventilated+cages/bio_rxiv__2025__04__27__650822-47-20-23
Average 90 stars, based on 1 article reviews
digitally ventilated cages (dvc) platform - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Tecniplast inc digital ventilated cages (dvcs) tecniplast s.p.a
Overview of the study design. This longitudinal study investigated the impact of stroke and Alzheimer’s disease on cognitive impairment, emphasizing sex differences. Male and female WT and APP swe /PS1 dE9 (APP/PS1) mice (3-month-old) were included. Baseline physiological parameters (body weight (BW) and systolic blood pressure (SBP)) were monitored. At 3.5 months of age, mice underwent either right transient middle cerebral artery occlusion (tMCAO) or sham surgery, resulting in eight groups: (1) male WT sham, (2) male WT stroke, (3) male APP/PS1 sham, (4) male APP/PS1 stroke, (5) female WT sham, (6) female WT stroke, (7) female APP/PS1 sham, and (8) female APP/PS1 stroke. Body weight and systolic blood pressure were monitored monthly post-stroke. Walking patterns of each mouse were individually monitored 24/7 for eight months using digital <t>ventilated</t> cages <t>(DVCs).</t> Magnetic resonance imaging (MRI) was conducted at 0.5, 4, and 8 months post-stroke. At 12 months of age (8 months post-stroke), spatial learning and memory were assessed using the Morris water maze (MWM) test. After the final neuroimaging session, mice were sacrificed, and brains were collected for post-mortem analysis, including immunohistochemical stainings, polarized light imaging, and biochemistry.
Digital Ventilated Cages (Dvcs) Tecniplast S.P.A, supplied by Tecniplast inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/digital+ventilated+cage+(dvc)+system/digital+ventilated+cages/pmc11944048-101-5-9
Average 90 stars, based on 1 article reviews
digital ventilated cages (dvcs) tecniplast s.p.a - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

Image Search Results


Overview of the study design. This longitudinal study investigated the impact of stroke and Alzheimer’s disease on cognitive impairment, emphasizing sex differences. Male and female WT and APP swe /PS1 dE9 (APP/PS1) mice (3-month-old) were included. Baseline physiological parameters (body weight (BW) and systolic blood pressure (SBP)) were monitored. At 3.5 months of age, mice underwent either right transient middle cerebral artery occlusion (tMCAO) or sham surgery, resulting in eight groups: (1) male WT sham, (2) male WT stroke, (3) male APP/PS1 sham, (4) male APP/PS1 stroke, (5) female WT sham, (6) female WT stroke, (7) female APP/PS1 sham, and (8) female APP/PS1 stroke. Body weight and systolic blood pressure were monitored monthly post-stroke. Walking patterns of each mouse were individually monitored 24/7 for eight months using digital ventilated cages (DVCs). Magnetic resonance imaging (MRI) was conducted at 0.5, 4, and 8 months post-stroke. At 12 months of age (8 months post-stroke), spatial learning and memory were assessed using the Morris water maze (MWM) test. After the final neuroimaging session, mice were sacrificed, and brains were collected for post-mortem analysis, including immunohistochemical stainings, polarized light imaging, and biochemistry.

Journal: Life

Article Title: Sex-Specific Adaptations in Alzheimer’s Disease and Ischemic Stroke: A Longitudinal Study in Male and Female APP swe /PS1 dE9 Mice

doi: 10.3390/life15030333

Figure Lengend Snippet: Overview of the study design. This longitudinal study investigated the impact of stroke and Alzheimer’s disease on cognitive impairment, emphasizing sex differences. Male and female WT and APP swe /PS1 dE9 (APP/PS1) mice (3-month-old) were included. Baseline physiological parameters (body weight (BW) and systolic blood pressure (SBP)) were monitored. At 3.5 months of age, mice underwent either right transient middle cerebral artery occlusion (tMCAO) or sham surgery, resulting in eight groups: (1) male WT sham, (2) male WT stroke, (3) male APP/PS1 sham, (4) male APP/PS1 stroke, (5) female WT sham, (6) female WT stroke, (7) female APP/PS1 sham, and (8) female APP/PS1 stroke. Body weight and systolic blood pressure were monitored monthly post-stroke. Walking patterns of each mouse were individually monitored 24/7 for eight months using digital ventilated cages (DVCs). Magnetic resonance imaging (MRI) was conducted at 0.5, 4, and 8 months post-stroke. At 12 months of age (8 months post-stroke), spatial learning and memory were assessed using the Morris water maze (MWM) test. After the final neuroimaging session, mice were sacrificed, and brains were collected for post-mortem analysis, including immunohistochemical stainings, polarized light imaging, and biochemistry.

Article Snippet: In this study, we utilized digital ventilated cages (DVCs) (Tecniplast S.p.A., Buguggiate (VA), Italy), which are equipped with sensing boards to continuously monitor the activity and location (centroids) of individually housed mice [ ].

Techniques: Magnetic Resonance Imaging, Immunohistochemical staining, Imaging